Tube en acier aluminisé Sa1c As80

Description

SA1C+AS80 combines a general-purpose steel substrate with a standard Al-Si coating. In the JIS-oriented aluminized steel system, this combination is positioned as an entry-level option for ordinary tube applications. It can be considered when moderate corrosion protection, practical forming, and controlled cost are more important than maximum coating weight or higher substrate performance.

What Does SA1C+AS80 Mean?

The designation contains two separate parts:

SA1C = ordinary-grade steel substrate

AS80 = approximately 80 g/m² total Al-Si coating weight, subject to the applicable specification and tolerance

The steel provides the basic mechanical structure. The aluminum-silicon coating provides improved oxidation and corrosion resistance compared with uncoated carbon steel in suitable environments.

It is important to keep the two designations separate. SA1C describes the substrate, while AS80 describes the coating. Changing AS80 to AS120 increases coating protection, but it does not change the underlying steel grade. Likewise, upgrading the substrate to SA1D does not automatically increase the coating weight.

Entry-Level JIS Combination for General Tubes

SA1C+AS80 is best viewed as a practical starting combination for ordinary service. It is suitable when the tube does not require unusually high mechanical properties, severe corrosion resistance, or the highest coating grade.

ArticleSA1C+AS80 ReferenceProcurement Meaning
SubstratSA1COrdinary-grade steel base
RevêtementAS80Standard Al-Si coating level
Typical positioningEntry / general purposeBalanced initial specification
FormulaireRond, oval, or other tube profilesConfirm production capability
ServiceGeneral indoor / outdoor useEnvironment must be checked
Coating basisg/m²Confirm exact standard and tolerance

The term “standard coating” here means a practical middle-entry coating level in the requested grade sequence. It should not be interpreted as a universal JIS requirement that every SA1C product must use AS80.

Typical SA1C+AS80 Tube Specifications

Actual dimensions depend on the tube manufacturing route and application. The following values can be used as practical inquiry examples:

ProfileExample SizeÉpaisseur de paroiLongueurRevêtement
Round tube25 mm OD1.0 mm6,000 mmAS80
Round tube38.1 mm OD1.2 mm6,000 mmAS80
Round tube50.8 mm OD1.5 mm6,000 mmAS80
Oval tube50 × 25 mm1.5 mm6,000 mmAS80

These are example specifications rather than fixed standard dimensions. For non-standard profiles, the buyer should provide a drawing showing the outside dimensions, épaisseur de paroi, tolérances, longueur, and required coating.

Where Is SA1C+AS80 Used?

The combination is suitable for applications where ordinary steel strength and a moderate Al-Si coating are sufficient.

Exhaust Tubes

Selected exhaust components and general exhaust tube applications where the actual temperature and atmosphere remain within the material design limits.

General Parts

Brackets, guards, equipment components, supports, and other ordinary fabricated parts.

Intérieur & De plein air

General indoor service and selected outdoor applications where corrosion exposure is not especially severe.

For exhaust applications, temperature should be checked separately. The AS80 designation alone does not establish a universal continuous-use temperature. Thermal cycling, atmosphere, tube wall thickness, substrate, formation, soudage, and coating condition all affect performance.

When Should You Upgrade to AS120?

AS120 is a logical upgrade when the main concern is more coating protection rather than higher substrate strength.

RequirementSA1C+AS80Consider SA1C+AS120
Mild environmentGood starting pointMay be unnecessary
More outdoor exposureCheck carefullyMore suitable candidate
Higher corrosion concernLimited marginBetter coating margin
Cost-sensitive general partsPreferred starting optionUpgrade if justified

Salt-spray results should also be compared only under the same test method, préparation des échantillons, exposure conditions, and failure criteria. Test hours should not be converted directly into a guaranteed outdoor service life.

When Should You Upgrade to SA1D?

Changing from SA1C to SA1D is a different decision. It concerns the steel substrate, not simply the coating.

SA1D should be considered when the application requires a different substrate performance level, forming behavior, or specification requirement. If the project specification calls for a particular mechanical property or forming grade, the substrate designation should be selected first. The coating grade can then be selected separately.

Simple upgrade rule: Need more surface protection? Consider moving from AS80 to AS120. Need different substrate performance? Review SA1C versus SA1D. Need both? Specify the upgraded substrate and coating together.

SA1C+AS80 Ordering Example

A clear inquiry should avoid using only the product name. A complete example can be written as:

Produit: SA1C+AS80 aluminized steel tube

Profile: Rond

Taille: 50.8 mm OD × 1.5 mm WT

Longueur: 6,000 mm

Revêtement: AS80

Quantity: 2,000 pcs

Application: General exhaust / fabricated component

This information gives the supplier enough detail to check dimensions, production feasibility, exigences en matière de revêtement, packing, and delivery conditions.

SA1C+AS80 Aluminized Tube in Stock

For standard sizes, stock availability can be an important advantage when a project needs short delivery. Teda Ganghua can support inquiries for tubes en acier aluminisé by checking available profiles, dimensions, coating grades, and quantities.

For repeat industrial orders, buyers can also specify the required substrate, AS coating grade, OD or profile dimensions, épaisseur de paroi, longueur, quantité, documents de contrôle, et exigences de traitement. This allows stocked material and production orders to be evaluated against the same technical specification.

SA1C+AS80 vs SA1C+AS120 vs SA1D+AS80

CombinationMain ChangeTypical Reason to Choose
SA1C+AS80Entry substrate + standard coatingGeneral-purpose, cost-conscious applications
SA1C+AS120Higher coating levelMore coating protection is required
SA1D+AS80Different substrate gradeSubstrate properties or forming requirements drive the choice

The best combination is therefore determined by the application, not by the coating grade alone. A lower-cost specification can be appropriate when the service environment is mild. An upgrade is justified when the actual operating conditions require additional performance.

FAQ

1. What does SA1C+AS80 mean?

SA1C identifies the ordinary steel substrate, while AS80 identifies the Al-Si coating level. They describe different parts of the product specification.

2. Is SA1C+AS80 suitable for exhaust pipe?

It can be suitable for selected general exhaust applications, but operating temperature, cyclage thermique, atmosphere, épaisseur de paroi, and coating condition must be checked before selection.

3. Should I choose AS120 instead of AS80?

Consider AS120 when additional coating protection is needed. La décision doit être basée sur l'exposition à la corrosion et les conditions de service plutôt que sur le seul poids du revêtement..

4. Quelle est la différence entre la mise à niveau d'AS80 et la mise à niveau de SA1C?

AS80 à AS120 modifie le niveau de revêtement. SA1C à SA1D modifie la spécification du substrat. Ils résolvent différentes exigences d’ingénierie.

5. Le tube SA1C+AS80 peut-il être fourni en stock?

Les tailles standard peuvent être disponibles en stock, en fonction des dimensions, profil, revêtement, et la quantité. Les acheteurs doivent fournir les spécifications complètes afin que le stock actuel puisse être vérifié avec précision.

Tuyau en acier au carbone aluminisé